Brand Name : Bestran

Model Number : BT-VD02

Certification : CE

Place of Origin : China

MOQ : 1pc

Price : Negotiable

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 500pcs per Month

Delivery Time : 3-5 days

Packaging Details : Packing size:51*42.5*27cm, 1pc/carton, N.W.:5.2KG, G.W.:8.6KG

Product : Vascular Doppler

Power : AC and DC Battery

Usage : Arterial and Venous Blood Flow Velocity

Display : Colour Touch LCD

Ultrasound frequency : 8MHz

USB Port : Yes

Probe detect : 8MHz

Ultrasound intensity : 10mW/cm2

Contact Now

AC DC Battery Vascular Doppler Flowmeter Arterial Venous Blood Flow Velocity Colour Touch LCD

1. Vascular Doppler Both AC and DC Battery Power:

  • Enhanced Mobility and Versatility: The dual power source feature (AC and DC battery) ensures that the Vascular Doppler can be used both in a clinical setting where mains power is available and in more mobile or remote environments where access to electricity is limited. Whether in an outpatient clinic, at a patient's home, or during emergency situations, the ability to run on DC battery power allows healthcare providers to perform diagnostic tests without interruptions.
  • Uninterrupted Functionality: Having both AC and DC battery power options ensures continuous operation during extended assessments. If the AC power supply is cut off or if the device is transported between locations, the device can switch seamlessly to battery mode. This minimizes downtime and enhances the reliability of the equipment, particularly in critical moments where monitoring and immediate feedback are needed.
  • Longer Battery Life and Efficiency: Modern Vascular Doppler devices are designed with energy efficiency in mind, allowing for longer usage times on battery power. This makes the device ideal for long-term use during procedures like ambulatory monitoring or when performing follow-up diagnostics in situations where charging access may not be readily available.
  • Convenient for Emergency Situations: In urgent care settings or emergency rooms, where a quick assessment of vascular conditions is crucial, the portability offered by battery power can be a lifesaver. Clinicians can perform quick diagnostics on patients without waiting for external power sources or being confined to a fixed location.

2. Vascular Doppler Arterial and Venous Blood Flow Velocity Measurement:

  • Comprehensive Vascular Assessment: The ability to measure Arterial and Venous Blood Flow Velocity allows for a complete evaluation of both arterial and venous health. This is particularly useful in diagnosing conditions such as peripheral arterial disease (PAD), deep vein thrombosis (DVT), varicose veins, and other circulatory issues. The measurement of both arterial and venous flow velocities helps provide a holistic picture of the patient’s vascular health, making the device a vital tool for a wide range of clinical applications.
  • Precise Diagnosis of Blood Flow Abnormalities: By measuring blood flow velocity, the Vascular Doppler helps detect abnormal flow patterns that can indicate issues like arterial blockages, narrowed arteries, or venous insufficiency. For example, in arterial monitoring, a decreased flow velocity may point to the presence of stenosis or atherosclerosis. In venous monitoring, an increased velocity or abnormal flow direction could suggest conditions like deep vein thrombosis (DVT) or venous reflux.
  • Non-invasive and Real-Time Monitoring: The real-time assessment of blood flow velocity through Doppler ultrasound allows clinicians to monitor vascular health without invasive procedures. This non-invasive approach is not only safer for patients but also offers immediate feedback during diagnostics, which can guide treatment decisions right away.
  • Evaluation of Treatment Progress: Monitoring the velocity of both arterial and venous blood flow before, during, and after treatment (such as stent placement, bypass surgery, or anticoagulation therapy) helps clinicians track the effectiveness of interventions. Changes in velocity can indicate improvements or complications in the vascular system, providing valuable insights into patient recovery and the success of interventions.

Vascular Doppler Technical Parameter:

Functions BT-VD01 BT-VD02
Display type B/W Colour
Display content Cursor Wave
Touch screen No Yes
Li-ion battery Yes Yes
Probe detect Yes Yes

Vascular Doppler Usage

BT-VD01/02vascular doppler is used to detect arterial and venous blood flow velocity to assess peripheral vascular disease, feasible in andrology, urology, surgery,surgical,microsurgery, orthopedics, vascular surgery, burns surgery and plastic surgery departments.

Vascular Doppler Features

● Sensitive special purpose probe

● Display with strength cursor (BT-VD01),with colour touch LCD (BT-VD02)

● Both of AC and DC battery

● Auto power off

● USB to transmit the data to computer

● Output with loudspeaker and earphone

Vascular Doppler Technical Specification

● Ultrasound frequency: 8MHz

● Ultrasound intensity: <10mW/cm2

● Power supply: 7.4V Li-ion Rechargeable battery

AC 220/110V, 50/60Hz

● Display: 65mm×50mm LCD

● Dimension :130mm ×100mm ×65mm

● Gross weight:About 600g

Vascular Doppler Configuration

● Main body

● Li-ion battery

● 8MHz probe

● Adaptor

Vascular Doppler Option

● Earphone

● Gel

● Carry case

Vascular Doppler Product Mode

● Neutral

● OEM

● ODM

● SKD

AC DC Battery Vascular Doppler Machine for Arterial and Venous Blood Flow VelocityAC DC Battery Vascular Doppler Machine for Arterial and Venous Blood Flow Velocity


Product Tags:

AC DC Battery Vascular Doppler

      

Colour Touch LCD Vascular Doppler

      

8MHz Ultrasound Vascular Doppler Machine

      
 AC DC Battery Vascular Doppler Machine for Arterial and Venous Blood Flow Velocity Manufactures

AC DC Battery Vascular Doppler Machine for Arterial and Venous Blood Flow Velocity Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhangjiagang Bestran Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)